PANASONIC 2.5HP NON-INVERTER R32 AIR COND

CS/CU-PN30XKH

Brand: PANASONIC
Availability: In Stock

RM3,628.00 RM5,200.00

Need more products enquiries? Chat With Us Now!

100% authentic

•  This item will be shipped from Malaysia
•  Estimated Shipping weight: 0.5 Kg
•  This item can be shipped to ALL destinations around the world
•  Item ship out within 1 - 7 days (excludes weekend and public holiday)
•  Tracking no. will be emailed to you once we have shipped your order

PANASONIC 2.5HP NON-INVERTER R32 AIR COND

Features

Instant Powerful Cooling with a Push of a Button

POWERFUL Mode will run both the compressor and indoor fan at super high speed, so you get to enjoy instant powerful cooling.

Instant Powerful Cooling with a Push of a Button

Comfort Cooling Environment for Your Needs

Long Airflow with Big Flap

Big bottom flap directs cooling and comforting air across the room for an optimal cooling sensation.

*Applicable to CS-PN9WKH-1 and CS-PN12WKH-1 only.

Long Airflow with Big Flap

Stay Cool with Faster, Further Airflow

AEROWINGS concentrates cool air for further and faster airflow across the room using 2 flaps. The sub-flap compresses and concentrates cool air, while the outer flap helps to deliver airflow further.

*Applicable to CS-PN18XKH-1B, CS-PN24XKH-1 and CS-PN30XKH-1 only.

Stay Cool with Faster, Further Airflow

Calm and Peaceful Environment with Quiet Mode

Loud noises can be bothersome. Switch on Quiet mode to reduce the noise level of the indoor unit. In Quiet mode, the fan speed is reduced to minimum. This mode is ideal when you require a quiet, peaceful environment, during rest time or study.

Calm and Peaceful Environment with Quiet Mode

Sleep Better at Night

A comfortable environment is essential for healthy sleep. Our body’s temperature decreases while we sleep, thus less cooling is required. Sleep mode offers ambient temperature by automatically shifting the set temperature during sleeping time.

Sleep Better at Night

Environmentally Friendly R32 Refrigerant

Panasonic air conditioners use environmentally friendly R32 refrigerant. An excellent heat transfer medium with a higher cooling capacity, this refrigerant reduces energy costs. It also has low global warming potential, making it friendlier to the environment.

Environmentally Friendly R32 Refrigerant

Fits Perfectly Anywhere

Panasonic air conditioners are designed to be compact enough to fit easily in tight, narrow spaces such as close to ceilings, close to corner walls, and above doors and windows. The designed structure makes installation and maintenance easy.

Fits Perfectly Anywhere

Convenient Control at Your Fingertips

The handheld wireless remote controller is easy to use, with commonly used functions for quick access.

*A wireless remote controller is included in the same package as the indoor unit. Product design may vary by models.

Convenient Control at Your Fingertips

Range

Model

Horsepower

1.0

1.5

2.0

2.5

3.0

Cooling Capacity

kW

2.78

3.52

5.33

6.85

8.80

Btu/h

9,500

12,000

18,200

23,400

30,000

Indoor Unit

CS-PN9WKH-1

CS-PN12WKH-1

CS-PN18XKH-1B

CS-PU24XKH-1

CS-PN30XKH-1

Outdoor Unit

CU-PN9WKH-1

CU-PN12WKH-1 

CU-PN18XKH-1B

CU-PU24XKH-1

CU-PN30XKH-1

 

  CS-PN9WKH-1_CU-PN9WKH-1 CS-PN12WKH-1_CU-PN12WKH-1 CS-PN18XKH-1B_CU-PN18XKH-1B CS-PN24XKH-1_CU-PN24XKH-1 CS-PN30XKH-1_CU-PN30XKH-1
Model Name PN9WKH-1 PN12WKH-1 PN18XKH-1B PN24XKH-1 PN30XKH-1
Cooling Capacity (kW) 2.78 kW 3.52 kW 5.33 kW 6.85 kW 8.80 kW
Cooling Capacity (Btu/h) 9,500 Btu/h 12,000 Btu/h 18,200 Btu/h 23,400 Btu/h 30,000 Btu/h
EER (Btu/hW) 11.59 Btu/hW 11.21 Btu/hW 11.23 Btu/hW 10.68 Btu/hW 12.40 Btu/hW
EER (W/W) 3.39 W/W 3.29 W/W 3.29 W/W 3.13 W/W 3.64 W/W
CSPF (W/W) 3.48 W/W 3.43 W/W 3.52 W/W 3.36 W/W -
Voltage (V) 230 V 230 V 230 V 230 V 230 V
Current (A) 3.7 A 4.8 A 7.1 A 9.7 A 10.6 A
Power Input (W) 820 W 1,070 W 1,620 W 2,190 W 2,420 W
Moisture Removal (L/h) 1.6 L/h 2.0 L/h 2.9 L/h 3.9 L/h 5.0 L/h
Moisture Removal (Pt/h) 3.4 Pt/h 4.2 Pt/h 6.1 Pt/h 8.2 Pt/h 10.6 Pt/h
Indoor Unit Air Circulation 10.9 m³/min (385 ft³/min) 11.6 m³/min (409 ft³/min) 18.4 m³/min (650 ft³/min) 20.5 m³/min (724 ft³/min) 25.5 m³/min (900 ft³/min)
Indoor Unit Noise Level (H / L / Q-Lo) 38/26 dB(A) 41/29 dB(A) 43/39 dB(A) 47/42 dB(A) 51/46 dB(A)
Indoor Unit Dimensions (H x W x D) (mm) 290 mm x 779 mm x 209 mm 290 mm x 779 mm x 209 mm 295 mm x 1,040 mm x 244 mm 295 mm x 1,040 mm x 244 mm 309 mm x 1,212 mm x 269 mm
Indoor Unit Dimensions (H x W x D) (inch) 11-7/16 inch x 30-11/16 inch x 8-1/4 inch 11-7/16 inch x 30-11/16 inch x 8-1/4 inch 11-5/8 inch x 40-31/32 inch x 9-5/8 inch 11-5/8 inch x 40-31/32 inch x 9-5/8 inch 12-3/16 inch x 47-23/32 inch x 10-19/32 inch
Indoor Unit Net Weight 8 kg (18 lb) 8 kg (18 lb) 12 kg (26 lb) 12 kg (26 lb) 16 kg (35 lb)
Outdoor Unit Air Circulation 28.8 m³/min (1,020 ft³/min) 29.8 m³/min (1,050 ft³/min) 39.3 m³/min (1,390 ft³/min) 40.3 m³/min (1,420 ft³/min) 54.4 m³/min (1,920 ft³/min)
Outdoor Unit Noise Level (H / L / Q-Lo) 48 dB(A) 51 dB(A) 53 dB(A) 55 dB(A) 56 dB(A)
Outdoor Unit Dimensions (H x W x D) (mm) 511 mm x 650 mm x 230 mm 542 mm x 780 mm x 289 mm 619 mm x 824 mm x 299 mm 619 mm x 824 mm x 299 mm 695 mm x 875 mm x 320 mm
Outdoor Unit Dimensions (H x W x D) (inch) 20-1/8 inch x 25-19/32 inch x 9-1/16 inch 21-11/32 inch x 30-23/32 inch x 11-13/32 inch 24-3/8 inch x 32-15/32 inch x 11-25/32 inch 24-3/8 inch x 32-15/32 inch x 11-25/32 inch 27-3/8 inch x 34-15/32 inch x 12-5/8 inch
Outdoor Unit Net Weight 21 kg (46 lb) 26 kg (57 lb) 35 kg (77 lb) 41 kg (90 lb) 53 kg (117 lb)
Refrigerant Pipe Diameter (Liquid Side) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch)
Refrigerant Pipe Diameter (Gas Side) ø 9.52 mm (3/8 inch) ø 9.52 mm (3/8 inch) ø 12.70 mm (1/2 inch) ø 15.88 mm (5/8 inch) ø 15.88 mm (5/8 inch)
Pipe Extension (Chargeless Pipe Length) 7.5 m 7.5 m 7.5 m 7.5 m 7.5 m
Pipe Extension (Maximum Pipe Length) 20 m 20 m 30 m 30 m 40 m
Pipe Extension (Maximum Elevation Length) 15 m 15 m 20 m 20 m 30 m
Pipe Extension (Additional Refrigerant Gas*) 10 g/m 10 g/m 15 g/m 25 g/m 25 g/m
Power Supply Indoor Indoor Indoor Indoor Outdoor
Sleep Mode Yes Yes Yes Yes Yes
Powerful Mode Yes Yes Yes Yes Yes
Soft Dry Operation Mode Yes Yes Yes Yes Yes
Quiet Mode Yes Yes Yes Yes Yes
Airflow Direction Control (Up & Down) Yes Yes Yes Yes Yes
Manual Horizontal Airflow Direction Control Yes Yes Yes Yes Yes
Odour Removing Function Yes Yes Yes Yes Yes
Removable Washable Panel Yes Yes Yes Yes Yes
24-Hour ON & OFF Real Setting Timer Yes Yes Yes Yes Yes
LCD Wireless Remote Control Yes Yes Yes Yes Yes
Wired Remote Control Yes (Optional) Yes (Optional) Yes (Optional) Yes (Optional) Yes (Optional)
Random Auto Restart Yes (32 Restart Patterns) Yes (32 Restart Patterns) Yes (32 Restart Patterns) Yes (32 Restart Patterns) Yes (32 Restart Patterns)
Blue Fin Condenser Yes Yes Yes Yes Yes
Long Piping (max.) 20 m 20 m 30 m 30 m 40 m
Top Panel Maintenance Access Yes Yes Yes Yes Yes
Note *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice.
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice.
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice.
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice.
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice.

Write a Review